Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Korean Journal of Radiology ; : 284-293, 2023.
Article in English | WPRIM | ID: wpr-968241

ABSTRACT

Objective@#To validate a simplified ordinal scoring method, referred to as modified length-based grading, for assessing coronary artery calcium (CAC) severity on non-electrocardiogram (ECG)-gated chest computed tomography (CT). @*Materials and Methods@#This retrospective study enrolled 120 patients (mean age ± standard deviation [SD], 63.1 ± 14.5 years; male, 64) who underwent both non-ECG-gated chest CT and ECG-gated cardiac CT between January 2011 and December 2021. Six radiologists independently assessed CAC severity on chest CT using two scoring methods (visual assessment and modified length-based grading) and categorized the results as none, mild, moderate, or severe. The CAC category on cardiac CT assessed using the Agatston score was used as the reference standard. Agreement among the six observers for CAC category classification was assessed using Fleiss kappa statistics. Agreement between CAC categories on chest CT obtained using either method and the Agatston score categories on cardiac CT was assessed using Cohen’s kappa. The time taken to evaluate CAC grading was compared between the observers and two grading methods. @*Results@#For differentiation of the four CAC categories, interobserver agreement was moderate for visual assessment (Fleiss kappa, 0.553 [95% confidence interval {CI}: 0.496–0.610]) and good for modified length-based grading (Fleiss kappa, 0.695 [95% CI: 0.636–0.754]). The modified length-based grading demonstrated better agreement with the reference standard categorization with cardiac CT than visual assessment (Cohen’s kappa, 0.565 [95% CI: 0.511–0.619 for visual assessment vs. 0.695 [95% CI: 0.638–0.752] for modified length-based grading). The overall time for evaluating CAC grading was slightly shorter in visual assessment (mean ± SD, 41.8 ± 38.9 s) than in modified length-based grading (43.5 ± 33.2 s) (P < 0.001). @*Conclusion@#The modified length-based grading worked well for evaluating CAC on non-ECG-gated chest CT with better interobserver agreement and agreement with cardiac CT than visual assessment.

2.
Journal of the Korean Radiological Society ; : 724-729, 2022.
Article in English | WPRIM | ID: wpr-926447

ABSTRACT

A duodenal web is an incomplete diaphragm of the duodenal lumen that causes a partial or (intermittent) complete obstruction. The size of a duodenal web’s aperture determines the degree of obstruction, age at presentation, and radiologic findings. We report a case of duodenal web incidentally diagnosed in a 14-month-old boy who presented to the hospital after ingesting a foreign body. We provide a comprehensive report of multiple studies through abdominal radiograph, upper gastrointestinal study, endoscopy, and surgical findings. We emphasize that the duodenum should be considered as the location of the obstruction when infants exhibit delayed discharge or dynamic positioning of a foreign body in a radiologic examination.

3.
Ultrasonography ; : 474-485, 2021.
Article in English | WPRIM | ID: wpr-919549

ABSTRACT

Purpose@#The aim of this study was to evaluate the diagnostic performance of the modified Korean Thyroid Imaging Reporting and Data System (K-TIRADS) compared with five society risk stratification systems (RSSs) according to nodule size. @*Methods@#In total, 3,826 consecutive thyroid nodules (≥1 cm) with final diagnoses in 3,088 patients were classified according to five RSSs. The K-TIRADS was modified by raising the biopsy size threshold for low-suspicion nodules and subcategorizing intermediate-suspicion nodules. We assessed the performance of the RSSs as triage tests and their diagnostic accuracy according to nodule size (with a threshold of 2 cm). @*Results@#Of all nodules, 3,277 (85.7%) were benign and 549 (14.3%) were malignant. In small thyroid nodules (≤2 cm), the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) had the highest reduction rate of unnecessary biopsies (76.3%) and the lowest sensitivity (76.1%). The modified K-TIRADS had the second highest reduction rate of unnecessary biopsies (67.6%) and sensitivity (86.6%). The modified K-TIRADS and ACR TI-RADS had the highest diagnostic odds ratios (P=0.165) and the highest areas under the curve (P=0.315). In large nodules (>2 cm), the sensitivity of the ACR TI-RADS for malignancy was significantly lower (88.8%) than the sensitivities of the modified K-TIRADS and other RSSs, which were very high (98.7%-99.3%) (P<0.001). @*Conclusion@#The modified K-TIRADS allows a large proportion of unnecessary biopsies to be avoided, while maintaining high sensitivity and diagnostic accuracy for small malignant tumors and very high sensitivity for large malignant tumors.

SELECTION OF CITATIONS
SEARCH DETAIL